Review




Structured Review

Matrixx Initiatives 2d ionization chamber array detector
2d Ionization Chamber Array Detector, supplied by Matrixx Initiatives, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/2d+ionization+chamber+array/2d+ion+chamber+array/pm39854837-171-17-16
Average 90 stars, based on 1 article reviews
2d ionization chamber array detector - by Bioz Stars, 2026-11
90/100 stars

Images

Related Articles

other:

Article Title: Improvement in clinical step and shoot intensity modulated radiation therapy delivery accuracy on an integrated linear accelerator control system.
Article Snippet: Purpose: The dose delivery accuracy of 30 clinical step and shoot intensity modulated radiation therapy plans was investigated using the single integrated multileaf collimator controller of the Varian Truebeam linear accelerator (linac) (Varian Medical Systems, Palo Alto, CA) and compared with the dose delivery accuracy on a previous generation Varian 2100CD C-Series linac.. Methods and Materials: Ten prostate, 10 prostate and pelvic node, and 10 head-and-neck cases were investigated in this study.. Dose delivery accuracy on each linac was assessed using Farmer ionization chamber point dosemeasurements, 2-dimensional planar ionization chamber arraymeasurements, and the corresponding Varian dynamic log files.

Article Title: Angular dependence correction of MatriXX and its application to composite dose verification
Article Snippet: We measured the angular dependence of central and off‐axis detectors in a 2D ionization chamber array, MatriXX, and applied correction factors (CFs) to improve the accuracy of composite dose verification of IMRT and VMAT.

Article Title: SU-GG-T-397: Voxel Size Effect on Dose Mass Histograms of Head and Neck- IMRT Monte Carlo Treatments
Article Snippet: In-vivo quantitative measurement of iron has been the focus of several studies related to iron disorders in the human body.. Techniques such as SQUID and MRI have been used to detect liver iron stores in patients afflicted with hemochromatosis and thalassemia.. Here we present a gammastimulated spectroscopy method to detect iron in an aqueous sample through nuclear resonance fluorescence.

Article Title: Sensitivity of array detector measurements in determining shifts of MLC leaf positions
Article Snippet: Using a MatriXX 2D ionization chamber array, we evaluated the detection sensitivity of systematically introduced MLC leaf positioning shifts to test whether the conventional IMRT QA method can be used for quality assurance of an MLC tracking algorithm.

Article Title: Breaking bad IMRT QA practice
Article Snippet: As with the film measurements, the MatriXX 2D ionization chamber array measurements were well within the published TG 119 action level threshold of 88%.

Article Title: Portal dosimetry for pretreatment verification of IMRT plan: a comparison with 2D ion chamber array
Article Snippet: In our Institute, pretreatment verification of IMRT plans have been carried out using the MatriXX 2D ionization chamber array and cross verification by 0.65 cc ionization chamber absolute point dose measurement, in case any discrepancies are found beyond our acceptable limit.

Article Title: Development of a video image-based QA system for the positional accuracy of dynamic tumor tracking irradiation in the Vero4DRT system.
Article Snippet: A target phantom was placed on the motion table, which was placed on the 2D ionization chamber array (MatriXX).



Similar Products

86
Liverage Biomedical Inc crossmini 2d strip ionization chamber detector array
Signal amplitude from the <t>CROSSmini</t> detector with signal fitting and zoomed in views. Figures A, B and C, on the left, shows the signal amplitude from the CROSSmini detector of a spill duration for energy level 70.2, 150.2, and 228.7 MeV, respectively, with nominal beam current 8 MU/s. The red line represents the original signal from CROSSmini and the black line represents the piecewise fitting for the edges. On the right is the zoomed in view of the fitting. The piecewise fitting quantifies the risetime ( t rise ) and measured nominal beam current ( I 0 , measured ).
Crossmini 2d Strip Ionization Chamber Detector Array, supplied by Liverage Biomedical Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/2d+ionization+chamber+array/pmc13138202-56-7-14
Average 86 stars, based on 1 article reviews
crossmini 2d strip ionization chamber detector array - by Bioz Stars, 2026-11
86/100 stars
  Buy from Supplier

90
IBA Dosimetry 2d ionization chamber array matrixxone
Signal amplitude from the <t>CROSSmini</t> detector with signal fitting and zoomed in views. Figures A, B and C, on the left, shows the signal amplitude from the CROSSmini detector of a spill duration for energy level 70.2, 150.2, and 228.7 MeV, respectively, with nominal beam current 8 MU/s. The red line represents the original signal from CROSSmini and the black line represents the piecewise fitting for the edges. On the right is the zoomed in view of the fitting. The piecewise fitting quantifies the risetime ( t rise ) and measured nominal beam current ( I 0 , measured ).
2d Ionization Chamber Array Matrixxone, supplied by IBA Dosimetry, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/2d+ionization+chamber+array/the+matrixx+evolution+2d+ionization+chamber+array/pmc12138570-65-15-20
Average 90 stars, based on 1 article reviews
2d ionization chamber array matrixxone - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
IBA Dosimetry 2d ionization chambers array matrixxpt
Signal amplitude from the <t>CROSSmini</t> detector with signal fitting and zoomed in views. Figures A, B and C, on the left, shows the signal amplitude from the CROSSmini detector of a spill duration for energy level 70.2, 150.2, and 228.7 MeV, respectively, with nominal beam current 8 MU/s. The red line represents the original signal from CROSSmini and the black line represents the piecewise fitting for the edges. On the right is the zoomed in view of the fitting. The piecewise fitting quantifies the risetime ( t rise ) and measured nominal beam current ( I 0 , measured ).
2d Ionization Chambers Array Matrixxpt, supplied by IBA Dosimetry, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/2d+ionization+chamber+array/the+matrixx+evolution+2d+ionization+chamber+array/pm39939287-194-25-30
Average 90 stars, based on 1 article reviews
2d ionization chambers array matrixxpt - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
IBA Dosimetry matrixx one is a 2d ionization chamber array
Signal amplitude from the <t>CROSSmini</t> detector with signal fitting and zoomed in views. Figures A, B and C, on the left, shows the signal amplitude from the CROSSmini detector of a spill duration for energy level 70.2, 150.2, and 228.7 MeV, respectively, with nominal beam current 8 MU/s. The red line represents the original signal from CROSSmini and the black line represents the piecewise fitting for the edges. On the right is the zoomed in view of the fitting. The piecewise fitting quantifies the risetime ( t rise ) and measured nominal beam current ( I 0 , measured ).
Matrixx One Is A 2d Ionization Chamber Array, supplied by IBA Dosimetry, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/2d+ionization+chamber+array/the+matrixx+evolution+2d+ionization+chamber+array/pm39854837-200-4-8
Average 90 stars, based on 1 article reviews
matrixx one is a 2d ionization chamber array - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Matrixx Initiatives 2d ionization chamber array detector
Signal amplitude from the <t>CROSSmini</t> detector with signal fitting and zoomed in views. Figures A, B and C, on the left, shows the signal amplitude from the CROSSmini detector of a spill duration for energy level 70.2, 150.2, and 228.7 MeV, respectively, with nominal beam current 8 MU/s. The red line represents the original signal from CROSSmini and the black line represents the piecewise fitting for the edges. On the right is the zoomed in view of the fitting. The piecewise fitting quantifies the risetime ( t rise ) and measured nominal beam current ( I 0 , measured ).
2d Ionization Chamber Array Detector, supplied by Matrixx Initiatives, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/2d+ionization+chamber+array/2d+ion+chamber+array/pm39854837-171-17-16
Average 90 stars, based on 1 article reviews
2d ionization chamber array detector - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Matrixx Initiatives pt 2d ionization chamber array detector
Signal amplitude from the <t>CROSSmini</t> detector with signal fitting and zoomed in views. Figures A, B and C, on the left, shows the signal amplitude from the CROSSmini detector of a spill duration for energy level 70.2, 150.2, and 228.7 MeV, respectively, with nominal beam current 8 MU/s. The red line represents the original signal from CROSSmini and the black line represents the piecewise fitting for the edges. On the right is the zoomed in view of the fitting. The piecewise fitting quantifies the risetime ( t rise ) and measured nominal beam current ( I 0 , measured ).
Pt 2d Ionization Chamber Array Detector, supplied by Matrixx Initiatives, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/2d+ionization+chamber+array/2d+ion+chamber+array/10__1016_slash_j__radphyschem__2024__111953-79-24-23
Average 90 stars, based on 1 article reviews
pt 2d ionization chamber array detector - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Matrixx Initiatives 2d ionization chamber array i’mrt
Signal amplitude from the <t>CROSSmini</t> detector with signal fitting and zoomed in views. Figures A, B and C, on the left, shows the signal amplitude from the CROSSmini detector of a spill duration for energy level 70.2, 150.2, and 228.7 MeV, respectively, with nominal beam current 8 MU/s. The red line represents the original signal from CROSSmini and the black line represents the piecewise fitting for the edges. On the right is the zoomed in view of the fitting. The piecewise fitting quantifies the risetime ( t rise ) and measured nominal beam current ( I 0 , measured ).
2d Ionization Chamber Array I’mrt, supplied by Matrixx Initiatives, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/2d+ionization+chamber+array/2d+ionization+chamber+array+i%E2%80%99mrt/pm38071091-176-15-16
Average 90 stars, based on 1 article reviews
2d ionization chamber array i’mrt - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
IBA Dosimetry 2d arrays with ionization chambers
Signal amplitude from the <t>CROSSmini</t> detector with signal fitting and zoomed in views. Figures A, B and C, on the left, shows the signal amplitude from the CROSSmini detector of a spill duration for energy level 70.2, 150.2, and 228.7 MeV, respectively, with nominal beam current 8 MU/s. The red line represents the original signal from CROSSmini and the black line represents the piecewise fitting for the edges. On the right is the zoomed in view of the fitting. The piecewise fitting quantifies the risetime ( t rise ) and measured nominal beam current ( I 0 , measured ).
2d Arrays With Ionization Chambers, supplied by IBA Dosimetry, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/2d+ionization+chamber+array/the+matrixx+evolution+2d+ionization+chamber+array/pmc10476988-46-27-41
Average 90 stars, based on 1 article reviews
2d arrays with ionization chambers - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
PTW Freiburg GmbH 2d ionization chamber array octavius detector 1500 xdr
(a) Measurement device combined with a <t>2D</t> <t>ionization</t> chamber array and an accordion-type water phantom. (b) Typical results for PSQA. The upper and lower panels show the PC and HNC cases, respectively. The arrows on the dose distribution indicate the dose profile’s direction. (c) The gamma passing rate in the clinical cases.
2d Ionization Chamber Array Octavius Detector 1500 Xdr, supplied by PTW Freiburg GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/2d+ionization+chamber+array/2d+ionization+chamber+array+octavius+detector+1500+xdr/pmc09089877-183-11-19
Average 90 stars, based on 1 article reviews
2d ionization chamber array octavius detector 1500 xdr - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

90
Matrixx Initiatives ionization chamber 2d array
(a) Measurement device combined with a <t>2D</t> <t>ionization</t> chamber array and an accordion-type water phantom. (b) Typical results for PSQA. The upper and lower panels show the PC and HNC cases, respectively. The arrows on the dose distribution indicate the dose profile’s direction. (c) The gamma passing rate in the clinical cases.
Ionization Chamber 2d Array, supplied by Matrixx Initiatives, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/2d+ionization+chamber+array/2d+ion+chamber+array/pm32634280-12687-11-17
Average 90 stars, based on 1 article reviews
ionization chamber 2d array - by Bioz Stars, 2026-11
90/100 stars
  Buy from Supplier

Image Search Results


Signal amplitude from the CROSSmini detector with signal fitting and zoomed in views. Figures A, B and C, on the left, shows the signal amplitude from the CROSSmini detector of a spill duration for energy level 70.2, 150.2, and 228.7 MeV, respectively, with nominal beam current 8 MU/s. The red line represents the original signal from CROSSmini and the black line represents the piecewise fitting for the edges. On the right is the zoomed in view of the fitting. The piecewise fitting quantifies the risetime ( t rise ) and measured nominal beam current ( I 0 , measured ).

Journal: International Journal of Particle Therapy

Article Title: Phenomenological Study of Intra-Spill Break Spots in Dose-Driven Continuous Scanning Proton Therapy

doi: 10.1016/j.ijpt.2026.101315

Figure Lengend Snippet: Signal amplitude from the CROSSmini detector with signal fitting and zoomed in views. Figures A, B and C, on the left, shows the signal amplitude from the CROSSmini detector of a spill duration for energy level 70.2, 150.2, and 228.7 MeV, respectively, with nominal beam current 8 MU/s. The red line represents the original signal from CROSSmini and the black line represents the piecewise fitting for the edges. On the right is the zoomed in view of the fitting. The piecewise fitting quantifies the risetime ( t rise ) and measured nominal beam current ( I 0 , measured ).

Article Snippet: The beam current was measured using a CROSSmini 2D strip ionization chamber detector array (Liverage Biomedical Inc, Taiwan) positioned at the isocenter plane.

Techniques:

Signal amplitude from the CROSSmini detector with signal fitting. shows the signal amplitude as a function of time measured by the CROSSmini detector and the piecewise fittings. Figures A, B, and C are measurements for energy level 70.2 MeV with nominal beam current 8, 14, and 20 MU/s, respectively. Figures D, E, and F are the measurements for energy level 228.7 MeV with nominal beam current 8, 14, and 20 MU/s, respectively.

Journal: International Journal of Particle Therapy

Article Title: Phenomenological Study of Intra-Spill Break Spots in Dose-Driven Continuous Scanning Proton Therapy

doi: 10.1016/j.ijpt.2026.101315

Figure Lengend Snippet: Signal amplitude from the CROSSmini detector with signal fitting. shows the signal amplitude as a function of time measured by the CROSSmini detector and the piecewise fittings. Figures A, B, and C are measurements for energy level 70.2 MeV with nominal beam current 8, 14, and 20 MU/s, respectively. Figures D, E, and F are the measurements for energy level 228.7 MeV with nominal beam current 8, 14, and 20 MU/s, respectively.

Article Snippet: The beam current was measured using a CROSSmini 2D strip ionization chamber detector array (Liverage Biomedical Inc, Taiwan) positioned at the isocenter plane.

Techniques:

t rise comparison between analytical and measured. The blue and red plots represent the analytically derived t rise and CROSSmini measured t rise , respectively, across the various nominal beam current settings.

Journal: International Journal of Particle Therapy

Article Title: Phenomenological Study of Intra-Spill Break Spots in Dose-Driven Continuous Scanning Proton Therapy

doi: 10.1016/j.ijpt.2026.101315

Figure Lengend Snippet: t rise comparison between analytical and measured. The blue and red plots represent the analytically derived t rise and CROSSmini measured t rise , respectively, across the various nominal beam current settings.

Article Snippet: The beam current was measured using a CROSSmini 2D strip ionization chamber detector array (Liverage Biomedical Inc, Taiwan) positioned at the isocenter plane.

Techniques: Comparison, Derivative Assay

(a) Measurement device combined with a 2D ionization chamber array and an accordion-type water phantom. (b) Typical results for PSQA. The upper and lower panels show the PC and HNC cases, respectively. The arrows on the dose distribution indicate the dose profile’s direction. (c) The gamma passing rate in the clinical cases.

Journal: PLoS ONE

Article Title: Commissioning a newly developed treatment planning system, VQA Plan, for fast-raster scanning of carbon-ion beams

doi: 10.1371/journal.pone.0268087

Figure Lengend Snippet: (a) Measurement device combined with a 2D ionization chamber array and an accordion-type water phantom. (b) Typical results for PSQA. The upper and lower panels show the PC and HNC cases, respectively. The arrows on the dose distribution indicate the dose profile’s direction. (c) The gamma passing rate in the clinical cases.

Article Snippet: We performed the measurements using the PinPoint chamber and a commercial 2D ionization chamber array (OCTAVIUS Detector 1500 XDR, PTW-Freiburg GmbH, Freiburg, Germany) mounted on an accordion-type water phantom that enables the water-equivalent thickness to be changed easily [ ].

Techniques: